Features

  • Pure Sine Wave Output
  • Built-in MPPT solar charge controller 80A
  • Support Remote Control Box(optional)
  • LCD display ,easy to read how inverter operates on LCD screen
  • Compatible to generator
  • 5-levels DIP switch ,offering customized performance
  • 9-levels battery selector ,Enable to charge Gel ,lead-acid battery
  • DC(Solar)/AC prority optional
  • 4 levels charge current adjustable
  • With RS232 communication port
  • With BTS & AGS , optimazing battery performance & start generator
    automatically
  • Power saver Switch , Enable to minimize standby consumption

Selection Guide

MODEL PV30-1KW
MPK
PV30-1.5KW
MPK
PV30-2KW
MPK
PV30-3KW
MPK
PV30-4KW
MPK
PV30-5KW
MPK
PV30-6KW
MPK
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 24VDC 48VDC
INVERTER OUTPUT Rated Power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Surge Rating (20ms) 3KW 4.5KW 6KW 9KW 12KW 15KW 18KW
Capable Of Staring Electric Motor 1HP 1HP 1HP 2HP 2HP 3HP 3HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V / 120V / 220V / 230V / 240VAC (±10% RMS) 110V/120V 220V/230V/240V 220V / 230V /240VAC
Output Frequency 50Hz/60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10(max)
AC INPUT Voltage 230VAC
Selectable Voltage Range 96~132VAC / 155~280VAC (For personal computer)
Frequency Range 50Hz/60Hz (Auto sensing) 40-80Hz
BATTERY Minimum Start Voltage 10.0VDC/10.5VDC for 12VDC mode (*2 for 24VDC) 20.0VDC~21.0VDC / 40.0VDC~42.0VDC
Low Battery Alarm 10.5VDC±0.3V for 12VDC mode (*2 for 24VDC) 21.0 VDC±0.6V / 42.0VDC±1.2V
Low Battery Cutoff 10.0VDC/±0.3V for 12VDC mode (*2 for 24VDC) 20.0 VDC±0.6V / 40.0VDC±1.2V
High Voltage Alarm 16.0VDC/±0.3V for 12VDC mode (*2 for 24VDC) 32.0 VDC±0.6V / 64.0VDC±1.2V
High Battery Voltage Recover 15.5VDC/±0.3V for 12VDC mode (*2 for 24VDC) 31.0 VDC±0.6V / 62.0VDC±1.2V
Idie Consumption Search Mode <25W when power saver on <50W when power saver on
AC CHARGER Output Voltage Depends on battery type
Charger AC Input Breaker Rating 10A 30A 30A 30A 40A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC) 31.4VDC/62.8VDC
Maximum Charge Current 35A 20A 45A 25A 65A 35A 75A 45A 65A 35A 70A 40A 75A 50A

BYPASS &

PROTECTION

Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
Bypass Breaker Rating 10A 15A 30A 30A 40A
Max Bypass Current 30Amp 40Amp
SOLAR CHARGER Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 2500W 5000W
Maximum PV Charge Current 80A 80A
DC Voltage 12V/24V auto work 24V/48V auto work
MPPT Range @ Operating Voltage 16~100VDC @ 12V/32~145VDC @ 24V 32~145VDC @ 24V/64~145VDC @ 48V
Maximum PV Array Open Circuit Voltage 145VDC
Maximum Efficiency >90% >98%
Standby Power Consumption <2W <2W

MECHANICAL

SPECIFICATIONS

Dimensions (W*H*D) 423*247*197 597*247*197
Net Weight (Solar CHG) (kg) 18.5 18.4 19.5 19.4 23.5 32.2 28.7 27 41.3 39.4 50.4 48.8 51.8 53.1
Shipping Dimensions (W*H*D) 570*355*300mm 597*247*197mm
Shipping Weight (Solar CHG) (kg) 21.5 21.4 22.4 22.5 25.8 25.6 31.2 29.6 44.7 42.8 54 52.4 55.7 53.1
OTHER Operation Temoerature Range 0 to 40
Storage Temperature Range -15 to 60
Audible Noise 60dB MAX
Loading (20GP/40GP/40HQ) 460pcs / 920pcs / 1060pcs 320pcs / 640pcs /750pcs