AGM Deep Cycle Battery 12V50Ah
General Features
- Designed floating charging service life: 12 years (25ºC)
- Sealed and maintenance free operation
- Safety valve installation for explosion proof
- Low self-discharge characteristic
- Wide operating temperature range from 0ºC~40ºC
- Lead Aluminum calcium Tin alloy high energy, prevent corrosion
APPLICATION
- DC power supply
- UP S /E P S power supply
- Electrical devices & instruments
- Security and fire alarm systems
- Telecom stations and power stations
- Medical equipments
- Emergency lighting systems
Physical Specifications
Nominal Voltage | Nominal Capacity (10HR ) |
Dimension | Weight ±3% | Internal Resistance (In full charge status) |
Standard Terminals |
|||
L | W | H | TH | |||||
12V | 50AH | 230±3mm | 138±2mm | 211±3mm | 216±3mm | Approx 15.8kg (34.8lbs) |
≈6.5mΩ | T25 (standard) |
Dimensions
Constant-Voltage Charge
Rated Capacity | |
20 hour rate (2.5A) | 53.0AH |
10 hour rate (5.0A) | 50.0AH |
5 hour rate (8.5A) | 42.5AH |
3 hour rate (12.5A) | 38.0AH |
1 hour rate (27.5A) | 28.0AH |
Capacity affected by Temperature | |
40ºC(104ºF ) | 103% |
25ºC(77ºF ) | 100% |
0ºC(32ºF ) | 86% |
Cycle Application |
1. Limit initial current less than 12.5A. |
2. Charge until battery voltage (under charge) reaches 14.1V to 14.4V at 25ºC(77ºF ) |
3. Hold at 14.1V to 14.4V until current drop to under0.30A for at least 3 hours |
4. Temperature compensation coefficient of charging voltage is -30mV/ºC |
Standby Service |
1. Hold battery across constant voltage source of 13.6 to 13.8 volts with current limit 12.5A continuously .When held at this voltage , the battery will seek its own current level and maintain itself in a fully charge status. |
2. Temperature compensation coefficient of charging voltage is -18mV/ºC. |
NOTE : The battery should be charged within 6 months of storage, Otherwise, permanent loss of capacity might occur as a result of sulfation
Battery Discharge Table
End Voltage (V) |
Minute (M) | Hour (H) | |||||||||||
5 | 10 | 15 | 30 | 45 | 1 | 1.5 | 2 | 3 | 5 | 8 | 10 | 20 | |
Constant Current Discharge Data Sheet (Amperes at 25ºC) | |||||||||||||
10.20 | 158 | 120 | 90.5 | 48.0 | 44.5 | 31.3 | 24.68 | 20.67 | 12.95 | 9.00 | 6.40 | 5.30 | 2.83 |
10.50 | 140 | 110 | 84.5 | 46.0 | 42.5 | 30.0 | 23.71 | 19.91 | 12.53 | 8.59 | 6.05 | 5.20 | 2.78 |
10.80 | 130 | 100 | 79.1 | 44.5 | 40.5 | 28.8 | 22.74 | 19.14 | 12.10 | 8.22 | 5.75 | 5.05 | 2.69 |
Constant Power Discharge Data Sheet (Watt at 25ºC) | |||||||||||||
10.20 | 1565 | 1325 | 962 | 599 | 450 | 391 | 285 | 215 | 160 | 103.2 | 76.5 | 65.0 | 34.05 |
10.50 | 1505 | 1125 | 864 | 585 | 440 | 385 | 281 | 208 | 155 | 100.0 | 75.5 | 63.0 | 33.00 |
10.80 | 1400 | 1050 | 825 | 573 | 425 | 368 | 268 | 201 | 150 | 96.5 | 74.5 | 60.0 | 32.25 |