AGM Deep Cycle Battery 12V100Ah
General Features
- Designed floating charging service life: 12 years (25ºC)
- Sealed and maintenance free operation
- Safety valve installation for explosion proof
- Low self-discharge characteristic
- Wide operating temperature range from 0ºC~40ºC
- Lead Aluminum calcium Tin alloy high energy, prevent corrosion
APPLICATION
- DC power supply
- UP S /E P S power supply
- Electrical devices & instruments
- Security and fire alarm systems
- Telecom stations and power stations
- Medical equipments
- Emergency lighting systems
Physical Specifications
Nominal Voltage | Nominal Capacity (10HR ) |
Dimension | Weight ±3% | Internal Resistance (In full charge status) |
Standard Terminals |
|||
L | W | H | TH | |||||
12V | 100AH | 331±3mm | 173±2mm | 216±3mm | 222±3mm | Approx 30.0kg (66.14lbs) |
≈4.53mΩ | T13 (standard) |
Dimensions
Constant-Voltage Charge
Rated Capacity | |
20 hour rate (2.5A) | 105.0AH |
10 hour rate (5.0A) | 100.0AH |
5 hour rate (8.5A) | 85.0AH |
3 hour rate (12.5A) | 76.0AH |
1 hour rate (27.5A) | 60.0AH |
Capacity affected by Temperature | |
40ºC(104ºF ) | 103% |
25ºC(77ºF ) | 100% |
0ºC(32ºF ) | 86% |
Cycle Application |
1. Limit initial current less than 25.0A. |
2. Charge until battery voltage (under charge) reaches 14.1V to 14.4V at 25ºC(77ºF ) |
3. Hold at 14.1V to 14.4V until current drop to under 0.60A for at least 3 hours |
4. Temperature compensation coefficient of charging voltage is -30mV/ºC |
Standby Service |
1.Hold battery across constant voltage source of 13.6 to 13.8 volts with current limit 25.0A continuously .When held at this voltage , the battery will seek its own current level and maintain itself in a fully charge status. |
2. Temperature compensation coefficient of charging voltage is -18mV/ºC. |
NOTE : The battery should be charged within 6 months of storage, Otherwise, permanent loss of capacity might occur as a result of sulfation
Battery Discharge Table
End Voltage (V) |
Minute (M) | Hour (H) | |||||||||||
5 | 10 | 15 | 30 | 45 | 1 | 1.5 | 2 | 3 | 5 | 8 | 10 | 20 | |
Constant Current Discharge Data Sheet (Amperes at 25ºC) | |||||||||||||
10.20 | 284 | 216 | 163 | 86.3 | 80.1 | 56.3 | 44.4 | 37.2 | 23.3 | 16.19 | 11.52 | 9.54 | 5.09 |
10.50 | 252 | 198 | 152 | 82.8 | 76.5 | 54.0 | 42.7 | 35.8 | 22.6 | 15.46 | 10.89 | 9.36 | 5.00 |
10.80 | 234 | 198 | 142 | 80.0 | 72.9 | 51.8 | 40.9 | 34.4 | 21.8 | 14.79 | 10.35 | 9.09 | 4.84 |
Constant Power Discharge Data Sheet (Watt at 25ºC) | |||||||||||||
10.20 | 2817 | 2385 | 1732 | 1078 | 810 | 704 | 513 | 386 | 288 | 186 | 138 | 117 | 61.3 |
10.50 | 2709 | 2025 | 1555 | 1053 | 792 | 693 | 505 | 374 | 279 | 180 | 136 | 113 | 59.4 |
10.80 | 2520 | 1890 | 1484 | 1031 | 765 | 662 | 482 | 361 | 269 | 174 | 134 | 108 | 58.1 |